QSFP28 SFP Transceiver Module 100G Fiber Optic Sfp Module For Backbone Network Solution

Brand Name : NEWBRIDGE

Model Number : ND-100GCFP- LR

Certification : FCC,CE

Place of Origin : SHENZHEN,CHINA

MOQ : 1PC

Price : Negotiation

Payment Terms : T/T , Western Union

Supply Ability : According to the different products , the monthly output is different

Delivery Time : According to the quantiy and stocking , 3-4 working days after payment

Packaging Details : packing can be done by customer's requested, usually used in carton

fiber : single mode

Device Type : optical SFP Module

Data rate : 100G

Operating temperature : 0°C to 70°C

distance : 10km

Fiber Connector : SC,FC,ST

Type : QSFP28 Fiber module

Contact Now

SFP Transceiver Module Finisar QSFP28 10km 100G transceiver fiber optic sfp module in backbone network solution

Product Features

● Supports up to 112Gbps bit rates

● Duplex LC connector

● Hot pluggable

● Operating electrical serial data rate up to 27.952493Gbps

● 4 parallel electrical serial interface

● Applicable for 10km SMF connection

● Low power consumption, < 9W

● Digital Diagnostic Monitor Interfacel ●MDIO Communication Interface

● Compliant with 100GBASE-LR4 and OTU4

● Operating case temperature:

Commerical:-20 to 75 °C

Applications

● Local Area Network(LAN)

● Wide Area Network(WAN)

● Switch to router interface

● ITU-T OTU4 OTL4.4

Standards

● Compliant with IEEE 802.3ba

● Compliant with CFP2 MSA hardware specifications

● Compliant with CFP2 MSA management specifications

● Compliant with ITU-T G709/Y.1331

● Compliant with RoHS

Functional Description

The 100G CFP2 LR4 optical transceiver integrates the transmit and receive path onto one module. On the transmit side, four lanes of serial data streams are recovered, retimed,and passed on to four laser drivers, which control four electric-absorption modulated lasers (EMLs) with 1296, 1300, 1305, and 1309 nm center wavelengths. The optical signals are then multiplexed into a single-mode fiber through an industry-standard LC connector.On the receive side, 4 lanes of optical data streams are optically demultiplexed by an integrated optical demultiplexer. Each data steam is recovered by a PIN photodetector and transimpedance amplifier, retimed, and passed on to an output driver. This module features a hot-pluggable electrical interface, low power consumption, and MDIO management interface.

Functional Diagram

QSFP28 SFP Transceiver Module 100G Fiber Optic Sfp Module For Backbone Network Solution

Absolute Maximum Ratings

Parameter Symbol Min. Max. Unit Note
Supply Voltage Vcc -0.5 3.6 V
Storage Temperature TS -40 85 °C
Relative Humidity RH 0 85 %

Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.

Recommended Operating Conditions

Parameter Symbol Min. Typ Max. Unit Note
Data Rate DR 103.2 11.3 Gb/s
Supply Voltage Vcc 3.14 3.3 3.46 V
Operating Case Temp. Tc 0 70 °C

Electrical Characteristics

(Tested under recommended operating conditions,unless otherwise noted)

Parameter Symbol Unit Min Typ Max Notes
Voltage Supply Electrical Characteristics
Supply Current Tx Section Icc A 3.75 1
Rx Section
Power Supply Noise Vrip 2% DC 1MHz
3% 1 10MHz

Total

Dissipation Power

Class1 Pw W 3
Class2 6
Class3 9
Class4 12
Low Power Mode Dissipation Plow W 2
Inrush Current Class1

and

I-inrush mA/usec 100
Turn-off Current Class2 I-turnoff mA/usec -100
Inrush Current Class3

and

I-inrush mA/usec 200
Turn-off Current Class4 I-turnoff mA/usec -200
Different Signal Electrical Characteristics
Single Ended Data Input Swing mV 20 525
Single Ended Data Output Swing mV 180 385
Differential Signal Output Resistance Ω 80 120
Differential Signal Input Resistance Ω 80 120
3.3V LVCMOS Electrical Characteristics
Input High Voltage 3.3VIH V 2.0 Vcc+0.3
Input Low Voltage 3.3VIL V -0.3 0.8
Input Leakage Current 3.3IIN uA -10 +10
Output HighVoltage (IOH=100uA) 3.3VOH V Vcc-0.2
Output Low Voltage (IOL=100uA) 3.3VOL V 0.2

Minimum Pulse Width of Control

Pin Signal

t_CNTL us 100
1.2V LVCMOS Electrical Characteristics
Input High Voltage 1.2VIH V 0.84 1.5
Input Low Voltage 1.2VIL V 0.3 1.2VIL V 0.36
Input Leakage Current 1.2IIN uA -100 +100
Output High Voltage 1.2VOH V 1.0 1.5
Output Low Voltage 1.2VOL V -0.3 0.2
Output High Current 1.2IOH mA -4
Output Low Current 1.2IOL mA +4
Input Capacitance Ci pF 10

High Speed Electrical Characteristics

Parameter Symbol Unit Min. Max. Notes
Impedance Zd Ω 90 110
Frequency MHz 161.1328125 1/64 of electrical lane rate
Frequency Stability △f ppm -100 100 For Ethernet
-20 20 For Telecom
Differential Voltage VDIFF mV 400 900 Peak to Peak Differential
Common mode noise (rms) mV 17.5
RMS jitter ps 10 Random Jitter Over frequency band of 10KHZ<f<10MHZ
Clock Duty Cycle % 40 60

Optical Characteristics

(Tested under recommended operating conditions,unless otherwise noted)

Parameter Symbol Unit Min Typ Max Notes
Optical Transmitter Characteristics
Signaling rate, each lane GBd 25.78125 ±100 ppm 100GBase-LR4
27.9525 ±20 ppm OTU4
Four Lane Wavelength Range λ1 nm 1294.53 1295.56 1296.59
λ2 1299.02 1300.05 1301.09
λ3 1303.54 1304.58 1305.63
λ4 1308.09 1309.14 1310.19
Total launch power dBm 10.5 100GBase-LR4
10 OTU4
Average launch power, each lane Pavg dBm -4.3 4.5 2
-0.6 4
Optical modulation amplitude, each lane (OMA)2 OMA dBm -1.3 4.5
Difference in launch power between any two lanes (OMA) dB 5
Extinction ratio ER dB 4 100GBase-LR4
4 6.5 OTU4
Side-mode suppression ratio SMSR dB 30
Transmitter and dispersion penalty, each lane TDP dB 2.2
Optical return loss tolerance dB 20
Transmitter reflectance3 dB –12
Transmitter eye mask {X1, X2, X3, Y1, Y2, Y3} {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} 100GBase-LR4
Optical Receiver Characteristics
Receive Rate for Each Lane Gbps 25.78125 27.9525
Overload Input Optical Power Pmax dBm 5.5 3

Average Receive Power for Each

Lane

Pin dBm -8.6 + ∆ 3 4, 5

Receive Power In OMA for Each

Lane

PinOMA dBm 3

Difference in Receive Power in

OMA between Any Two Lanes

dBm

Receiver Sensitivity in OMA for

Each Lane

SOMA dBm -8.6 6

Stressed Receiver Sensitivity in

OMA for Each Lane

dBm -6.8 7, 8

Notes:

1. The supply current includes CFP2 module’s supply current and test board workingcurrent.

2. Average launch power, each lane (min) is informative for 100GBase-LR4, not the principal indicator of signal strength.

3.The receiver shall be able to tolerate , without damage, continuous exposure to an optical input signal having this average power level

4. The average receive power , each lane (max) for 100GBASE-ER4 is larger than the

100BASE-ER4 transmitter value to allow compatibility with 100BASE-LR4 units at short distances

5. Average receive power, each lane (min) is informative and not the principal indicator

of signal strength. A received power below this value cannot be compliant; however, a value above this does not ensure compliance

6. Receiver sensitivity (OMA), each lane (max) is informative

7. Measured with conformance test signal at TP3 for BER=10-12

8. conditions of stressed receiver sensitivity test: vertical eye closure penalty for each lane is 1.8dB;stressed eye J2 jitter for each lane is 0.3UI; stressed eye J9 jitter for each lane is 0.47UI.

Pin Name I/O Logic Description
1 GND
2 (TX_MCLKn) O CML For optical waveform testing. Not for normal use.
3 (TX_MCLKp) O CML For optical waveform testing. Not for normal use.
4 GND
5 N.C No Connect
6 N.C
7 3.3V_GND 3.3V Module Supply Voltage Return Ground, can be separate or tied together with Signal Ground
8 3.3V_GND
9 3.3V 3.3V Module Supply Voltage
10 3.3V
11 3.3V
12 3.3V
13 3.3V_GND 3.3V Module Supply Voltage Return Ground, can be separate or tied together with Signal Ground
14 3.3V_GND
15 VND_IO_A I/O Module Vendor I/O A. Do Not Connect!
16 VND_IO_B I/O Module Vendor I/O A. Do Not Connect!
17 PRG_CNTL1 I LVCMOS w/ PUR Programmable Control 1 set over MDIO, MSA Default: TRXIC_RSTn, TX & RX ICs reset, "0": reset, "1" or NC: enabled = not used
18 PRG_CNTL2 I LVCMOS w/ PUR Programmable Control 2 set over MDIO, MSA Default: Hardware Interlock LSB, "00": ≤3W, "01": ≤6W, "10": ≤9W, "11" or NC: ≤12W = not used
19 PRG_CNTL3 I LVCMOS w/ PUR Programmable Control 2 set over MDIO, MSA Default: Hardware Interlock LSB, "00": ≤3W, "01": ≤6W, "10": ≤9W, "11" or NC: ≤12W = not used
20 PRG_ALRM1 O LVCMOS Programmable Alarm 1 set over MDIO, MSA Default: HIPWR_ON, "1": module power up completed, "0": module not high powered up
21 PRG_ALRM2 O LVCMOS Programmable Alarm 2 set over MDIO, MSA Default: MOD_READY, "1": Ready, "0": not Ready.
22 PRG_ALRM3 O LVCMOS Programmable Alarm 3 set over MDIO, MSA Default: MOD_FAULT, fault detected, "1": Fault, "0": No Fault
23 GND
24 TX_DIS I LVCMOS w/ PUR Transmitter Disable for all lanes, "1" or NC = transmitter disabled, "0" = transmitter enabled
25 RX_LOS O LVCMOS Receiver Loss of Optical Signal, "1": low optical signal, "0": normal condition
26 MOD_LOPWR I LVCMOS w/ PUR Module Low Power Mode. "1" or NC: module in low power (safe) mode, "0": power-on enabled
27 MOD_ABS O GND Module Absent. "1" or NC: module absent, "0": module present, Pull Up Resistor on Host
28 MOD_RSTn I LVCMOS w/ PDR Module Reset. "0" resets the module, "1" or NC = module enabled, Pull Down Resistor in Module
29 GLB_ALRMn O LVCMOS Global Alarm. “0": alarm condition in any MDIO Alarm register, "1": no alarm condition, Open Drain, Pull Up Resistor on Host
30 GND
31 MDC I 1.2VCMOS Management Data Clock (electrical specs as per IEEE Std 802.3ae-2008 and ba-2010)
32 MDIO I/O 1.2VCMOS Management Data I/O bi-directional data (electrical specs as per IEEE Std 802.3ae-2008 and ba-2010)
33 PRTADR0 I 1.2VCMOS MDIO Physical Port address bit 0
34 PRTADR1 I 1.2VCMOS MDIO Physical Port address bit 1
35 PRTADR2 I 1.2VCMOS MDIO Physical Port address bit 2
36 VND_IO_C I/O Module Vendor I/O C. Do Not Connect!
37 VND_IO_D I/O Module Vendor I/O D. Do Not Connect!
38 VND_IO_E I/O Module Vendor I/O E. Do Not Connect!
39 3.3V_GND
40 3.3V_GND
41 3.3V 3.3V Module Supply Voltage
42 3.3V
43 3.3V
44 3.3V
45 3.3V_GND
46 3.3V_GND
47

N.C

No Connect

48

N.C

49

GND

50

(RX_MCLKn)

O CML For optical waveform testing. Not for normal use.
51

(RX_MCLKp)

O CML
52 GND
53 GND
54 N.C.
55 N.C.
56 GND
57 RX0p 25 Gbps receiver data; Lane 0
58 RX0n 25 Gbps receiver data bar; Lane 0
59 GND
60 RX1p 25 Gbps receiver data; Lane 1
61 RX1n 25 Gbps receiver data bar; Lane 1
62 GND
63 N.C.
64 N.C.
65 GND
66 N.C.
67 N.C.
68 GND
69 RX2p 25 Gbps receiver data; Lane 2
70 RX2n 25 Gbps receiver data bar; Lane 2
71 GND
72 RX3p 25 Gbps receiver data; Lane 3
73 RX3n 25 Gbps receiver data bar; Lane 3
74 GND
75 N.C.
76 N.C.
77 GND
78 (REFCLKp) CML Module reference clock. No connect.
79 (REFCLKn) CML Module reference clock. No connect.
80 GND
81 N.C.
82 N.C.
83 GND
84 TX0p 25 Gbps transmitter data; Lane 0
85 TX0n 25 Gbps transmitter data bar; Lane 0
86 GND
87 TX1p 25 Gbps transmitter data; Lane 1
88 TX1n 25 Gbps transmitter data bar; Lane 1
89 GND
90 N.C.
91 N.C.
92 GND
93 N.C.
94 N.C.
95 GND
96 TX2p 25 Gbps transmitter data; Lane 2
97 TX2n 25 Gbps transmitter data bar; Lane 2
98 GND
99 TX3p 25 Gbps transmitter data; Lane 3
100 TX3n 25 Gbps transmitter data bar; Lane 3
101 GND
102 N.C.
103 N.C.
104 GND

Hardware Control Pins

The CFP2 Module support real-time control functions via hardware pins, listed in the following

Pin Symbol Description I/O Logic H L Pull-up/down
17 PRG_CNTL1

Programmable Control 1

MSADefault:TRXIC_RST

n , TX&RX ICs reset,

“0”:reset;”1”

I

3.3V

LVCMOS

per CFP MSA

Management

Interface

Specification

Pull-Up

Note1

18

PRG_CNTL2

Programmable Control 2

MSADefault :Hardware

Interlock LSB

I

3.3V

LVCMOS

Pull-Up

Note1

19 PRG_CNTL3

Programmable Control 3

MSA Default:Hardware

Interlock MSB

I

3.3V

LVCMOS

Pull-Up

Note1

26 MOD_LOPWR Module Low Power Mode I

3.3V LVCMOS Low Power

Enable Pull-Up

Low

Power

Enable

Pull-Up

Note1

28 MOD_RSTn Module Reset(Invert) I

3.3V

LVCMOS

Enable Reset

Pull-Down

Note2

Notes:

1. Pull-Up resistor (4.7KOhm to 10 KOhm) is located within the CFP2 module

2. Pull-Down resistor (4.7KOhm to 10 kOhm) is located within the CFP2 module

Hardware Alarm Pins

The CFP2 Module supports alarm hardware pins listed in the following

Pin Symbol Description I/O Logic H L Pull-up/down
20

PRG_ALRM

1

Programmable

Alarm 1

MSA

Default:HIPWR_ON

O 3.3V LVCMOS

Active High per

MDIO document

21 PRG_ALRM2

Programmable

Alarm 2

MSA

default:MOD_READY

, Ready

State has been

reached

O 3.3V LVCMOS
22

PRG_ALRM

3

Programmable

Alarm 3

MSA Default: MOD_FAULT

O 3.3V LVCMOS
27 MOD_ABS Module Absent O 3.3V LVCMOS Absent Present

Pull-Down

Note1

25 RX_LOS

Receiver Loss of

Signa

O 3.3V LVCMOS

Loss of

Signal

OK

Note:

1:.Pull-Down resistor (<100Ohm) is located within the CFP2 module. Pull-up should be located on the host

Management Interface Pins(MDIO)

The CFP2 Module supports alarm, control and monitor functions via an MDIO bus. The CFP2 MDIO pins are listed in the following:

. Symbol Description I/O Logic H L Pull-up/down
29 GLB-ALRMn Global Alarm I

3.3V

LVCMOS

OK Alarm
32 MDIO

Management interface bidirectional

data

I/O 1.2V LVCMOS
31 MDC Management interface clock input I 1.2V LVCMOS
33 PRTADR0 MDIO physical port address bit 0 I 1.2V LVCMOS Per MDIO
34 PRTADR1 MDIO physical port address bit 1 I 1.2V LVCMOS
35 PRTADR2 MDIO physical port address bit 2 I 1.2V LVCMOS

Hardware Signaling Pin Timing Requirements

Timing Parameters for CFP2 hardware Signal Pins are listed in the following:

Parameter Symbol Unit Min. Max. Notes
Hardware MOD_LOPWR assert t_MOD_LOPWR_assert ms 1
Hardware MOD_LOPWR deassert t_MOD_LOPWR_deassert s 60 Stored in NVR register 8072h
Management interface clock period t_prd ns 250 MDC is 4 MHz rate or less
Host MDIO setup time t_setup ns 10
Host MDIO hold time t_hold ns 10
CFP2 MDIO delay time t_delay ns 0 175
GLB_ALRM assert time GLB_ALRMn_assert ms 150

A logic “OR” of associated MDIO alarm and

status registers

GLB_ALRM deassert time GLB_ALRMn_deassert ms 150

A logic “OR” of associated MDIO alarm and

status registers

Minimum pulse width of control pin signal t_CNTL μs 100
Initialization time from reset t_initialize s 2.5
TX_Disable assert time t_deassert μs 100 Transmitter disable, application specific
TX_Disable deassert time1 t_assert ms Product Tags:

optical transceiver module

      

fiber sfp module

      
Quality QSFP28 SFP Transceiver Module 100G Fiber Optic Sfp Module For Backbone Network Solution for sale

QSFP28 SFP Transceiver Module 100G Fiber Optic Sfp Module For Backbone Network Solution Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Newbridge Communication Equipment Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)